Description
Hioki CT6704 Current Probe for High-Frequency Current Measurement
The Hioki CT6704 Current Probe is designed for engineers who need to observe fast, high-current waveforms with confidence. Built for demanding power electronics applications, this current probe combines a wide DC to 30 MHz bandwidth with continuous current measurement up to 200 A RMS. Its advanced fluxgate sensing technology also helps reduce thermal drift and inductive heating, allowing users to capture more stable waveforms during demanding measurements.
This makes the CT6704 particularly useful for modern power conversion systems where fast switching transitions can have a major impact on efficiency, reliability and overall design performance.
30 MHz Bandwidth
Fast switching devices can create current waveforms with very short transitions and high-frequency components. A current probe with limited bandwidth may hide important details of these signals. The CT6704 provides bandwidth from DC to 30 MHz, allowing engineers to examine fast waveform changes in greater detail.
The probe also offers a rise time of 11.6 ns or shorter. This fast response makes it suitable for observing switching transitions in advanced semiconductor applications, including systems based on silicon carbide and gallium nitride devices.
SiC and GaN Testing
Modern SiC and GaN power devices can switch extremely quickly. Even small parasitic ripples can affect switching performance and power converter behavior. The CT6704 provides the bandwidth needed to observe these details during measurements such as double-pulse testing.
By capturing the current waveform with high temporal resolution, engineers can better evaluate switching behavior, characterize switching losses and validate power converter designs. This can support more informed design decisions during development and verification.
Stable Fluxgate Sensing
High-current measurement at high frequencies can cause heating inside a current probe. Excessive heating may limit measurement conditions and introduce waveform drift during longer tests.
The CT6704 uses fluxgate sensing technology to reduce the effects of self-heating and thermal drift. This helps maintain stable waveform observation as measurement time increases or ambient temperature changes. HIOKI specifically designed the CT6704 and CT6705 to reduce inductive heating under high-current, high-frequency conditions.
This stability is valuable when engineers need to perform extended measurements without constantly adjusting the test setup.
High-Current Testing
The CT6704 can continuously measure up to 200 A RMS under specified conditions. It also supports a maximum allowable peak input of ±400 A for up to 2 seconds. These capabilities make it suitable for high-current power electronics where both steady-state current and transient behavior need to be evaluated.
The probe is designed for insulated conductors and has a 20 mm core diameter. Its 0.01 V/A output rate provides a straightforward signal interface for compatible measurement equipment.
BNC Output
The CT6704 uses a standard BNC output, giving engineers flexibility when connecting it to oscilloscopes and other compatible waveform measurement systems. This allows the same current probe to be used across different laboratory platforms and oscilloscope brands.
The probe can also connect directly to the Hioki MR6000 Memory HiCorder, which provides sensor power and supports an integrated Hioki measurement and recording setup. This flexibility can be useful for laboratories that work with multiple measurement platforms.
Long Measurements
Long measurement sessions can expose weaknesses in conventional current sensing methods. As the probe heats up, its output can drift and make waveform comparisons more difficult.
The CT6704 is designed to minimize this issue. Its fluxgate-based sensing system reduces the effects of self-heating, helping engineers maintain stable waveform observation during extended measurements. The result is a measurement solution that supports more consistent analysis across longer test periods.
Applications
The CT6704 is suited to a range of high-frequency and high-current applications. Typical uses include:
- SiC and GaN power semiconductor testing
- Double-pulse testing
- Power converter development
- Switching loss analysis
- High-frequency inverter testing
- Power supply development
- High-current transient measurement
- BBU load variation testing
- Advanced laboratory waveform analysis
Its combination of wide bandwidth, high current capacity and thermal stability makes it particularly useful when engineers need to see the actual current waveform rather than rely on slower or narrower measurement methods.
Specifications
| Specification | Details |
| Product type | High-bandwidth Current Probe |
| Frequency bandwidth | DC to 30 MHz, -3 dB |
| Continuous allowable input | 200 A RMS |
| Maximum allowable peak input | ±400 A peak within 2 seconds |
| Rise time | 11.6 ns or shorter |
| Noise level | 25 mA RMS typical with 20 MHz bandwidth instrument |
| Amplitude accuracy | ±0.5% rdg. ±0.5 mV at DC and 45 to 66 Hz, 0 to 200 A RMS |
| Peak amplitude accuracy | ±1% rdg. at DC and 45 to 66 Hz, 200 to 400 A peak |
| Output rate | 0.01 V/A |
| Output connection | BNC |
| Measurable conductor | Insulated conductor |
| Core diameter | 20 mm |
| Power supply | ±12 V ±0.5 V, 7.2 VA |
| Sensor dimensions | 163 × 67 × 23 mm |
| Junction box dimensions | 45 × 120 × 26 mm |
| Sensor and junction box mass | Approx. 425 g |
| Sensor cable | Approx. 1.5 m |
| Sensor to junction box cable | Approx. 1.7 m |
| Junction box to BNC cable | Approx. 0.3 m |
| Power cord length | Approx. 1 m |
| Included accessories | Instruction manual and carrying case |
| Accuracy guarantee | 1 year |
Click here to learn more about similar products from HIOKI E E CORPORATION